Custom Technology has been in the business of producing drivers for over 10 years with unmatched success. Below is a list of current drivers that work with FIX, FIX/DMACS, Genesis, Wonderware, Paragon and SCADIX and the stats along with them. If you have any questions please do not hesitate to contact us DDE2TCP, Collect and pipe data via TCP/IP: Driver/Program
developed to gather real-time data from DDE capable programs and transmit
it via TCP/IP. This program was specifically designed for gathering real-time
information from MMI programs such as FIX, WONDERWARE, GENESIS, LABTECH
NOTEBOOK and send it to UNIX machines. It will gather any type of information
via DDE and transmit it via TCP/IP SOCKETS to any destination and can support
multiple DDE conversations. "DDE2TCP" will run on WINDOWS v3.1, WINDOWS/NT
and WINDOWS 95. Price $395.00
BARBER COLEMAN MAQ PID CONTROLLERS: This driver is
available under DOS, WINDOWS and OS/2. This is a read/write driver that
will not only talk to an individual PID controller but it can talk over
the BARBER_COLEMAN multi drop network. This means that an individual PID
controller can be linked to a FIX SCADA unit but have access to 32 other
PID controllers on the network. Price
$750.00
GAUGEPORT: by Observation
Systems, this driver is available under DOS, WINDOWS and OS/2. This driver
is a read only driver and will allow the interface to a myriad of gauges
measuring devices. Price
$750.00
PMS 2500 PARTICLE COUNTER: This driver is
available under DOS and WINDOWS. It is a read only driver that will read
serial output of the particle size populations in a gas stream.Price
$1000.00
PMS Particle Measuring Systems Interface: This driver is
used to communicate with the LASAIR HS110 Aresol particle counter and also
the HSLIS Particle Counter for Liquids. This a Read ONLY driver via RS-232,RS-422/485
or TCP/IP (via a Lantronix device). This driver will read all Real Time
data transmitted. In the case of the LASAIR unit the driver will handle
the option of multiple samples taken by a single LASAIR unit. The driver
can handle up to 24 different manifold positions. In the case of the HSLIS
liquid particle counter, for data to be retrieved the unit must have the
PDSPB data device attached. The driver can accomidate up to 4 LASAIR units
and 4 HSLIS units (Lantronix required) simmultaneously. FIX/NT and Wonderware
are supported. A standalone version is also available. This product is
available through Custom Technology. Price
$2500
AEONIC GAUGING SYSTEM: This driver links directly into the DECNET interface system that AEONIC provides. This is available under DOS, WINDOWS and OS/2. It is primarily a read only driver for all data that is generated during extrusion such as:
Price $1500.00 This driver is
available under DOS and WINDOWS. This driver is a read only program gathering
die bolt information on a timely basis. Price
$1500.00
ATI Beta Gauge: This driver is
used in conjunction with Analog Devices CTM-05 counter card and is available
under DOS and WINDOWS. It will allow the user to display the beta count
over time. If the user attached the system to a moving platform over the
target web, the driver allows for multiple stored/displayed values. This
allows the user to show how die bolt positions effect thickness of the
extruded plastic. Price
$1000.00
STAEFA Serial Interface Driver: This driver is used in conjunction with the ATKINS TTL convertor. This program would be used to Read and Write to Smart I and Smart II I/O cards. It will allow the replacement of the main STAEFA controller card. This program also can be easily used with any MMI system i.e. FIX,Wonderware,Factorylink. Price $2500 TIBCO Rendezvous Message Bus: This driver is
used to interface the TIBCO message bus. WONDERWARE and FIX MMI systems
can subscribe to any message transmitted accross the TIBCO BUS. This
driver
CSI, Control Systems International Interface: This driver is
used to communicate with control devices that are connected to the sublan
of a MRI. This a Read ONLY driver via RS-232,RS-422/485. It will allow
the replacement of CSI's main MRI controller card. This program also can
be used with any MMI system i.e. FIX,Wonderware,Factorylink. Price
$2500
ANDOVER HVAC: This driver is
available under WINDOWS only. This driver has two parts that can be purchased
separately but can also work together on the same SCADA node:
This FIX,
WONDERWARE, LABVIEW driver will allow the real time interface to the CM4
via RS-232 or RS-422. There are 64 different I/O properties available to
the FIX system, all with a maximum of 1.5 sec refresh rate. The CM4 allows
four gas streams to be analyzed simultaneously. The driver is available
for: WINDOWS FIX, NT DMACS, Specifix, WONDERWARE, LabView and as a stand
alone program for windows. Price $2500.00
ZELLWEGER - MDA Scientific G.D.A.C.S. Multipoint Gas Analyzer This driver has
all of the same capabilities as the CM4 driver. The program, however, is
for the older G.D.A.C.S. system and is a READ ONLY driver. The driver is
available for: WINDOWS DMACS, NT DMACS, Specifix and as a stand alone program
for WINDOWS. Price $750.00
ZELLWEGER - MDA Scientific System 16 Gas Analyzer This driver has
all of the same capabilities as the CM4 driver. The program, however, is
for the System 16 system which can handle 16 simultaneous gas streams.
This driver is a READ ONLY driver. The driver is available for: Wonderware,
NT FIX, Specifix and as a stand alone program for NT. Price
$2500.00
WIZDOM CONTROLS SOURCE CARD: This driver is a full functioning bi-directional link into the WIZDOM source card. This is a dual ported RAM interface available for FIX, GENESIS, WONDERWARE, PARAGON, FACTORYLINK. This driver is a bi-directional link that can support over 5,000 I/O points with an update speed of 1.1 sec. This program is also available as a a stand alone WINDOWS program. Price $750.00 Custom Technology is also available to produce custom drivers and custom installations at a reasonable price. For more information feel free to call us, or send us a message. |